EcoFlow RIVER 2 Pro Runtime Calculator

Quick answer: the EcoFlow RIVER 2 Pro stores 768 Wh and delivers up to 800 W of continuous AC power. Under this site's planning assumptions (85% inverter efficiency, 10% reserve), a steady 100 W AC load runs for roughly 5.9 hours. Last source check: 2026-08-21. This is an estimate, not a guarantee.

EcoFlow RIVER 2 Pro portable power station
Battery capacity768 Wh
AC output800 W
Surge output1,600 W
Battery chemistryLFP
ConfidenceVerified
Source regionGlobal/general sources
checked2026-08-21
Swipe table sideways
EcoFlow RIVER 2 Pro: Key facts
Battery capacity768 Wh
Battery chemistryLFP
AC output800 W
Surge output1,600 W
DC output126 W
USB-C output100 W
Solar input220 W
Weight8.25 kg
ConfidenceVerified
Lifecycle statusUnknown
Source regionGlobal/general sources
Last verified2026-08-21
Catalog notes (original English)

The 1,600W value is retained because EcoFlow's exact specification publishes it as surge separately from the 800W rated AC output.

Measurement Records

Third-party results apply to the listed model, output path and test load. The delta is against a fixed no-reserve planning formula, not an error score or a prediction at other loads. Missing test conditions remain unknown.

Swipe table sideways
Measurement Records: EcoFlow RIVER 2 Pro
TestMeasureddefault planning estimateVs estimateSource
Capacity test (AC)
Average test load: unknown
test date unknown
620 Wh
81%
653 Wh-33 Wh (-5%)OutdoorGearLab Best Power Stations of 2026
source date unknown; accessed 2026-09-04
Capacity test (AC)
Average test load: unknown
test date unknown
640 Wh
83%
653 Wh-13 Wh (-2%)HoboTech EcoFlow River 2 Pro review
2023-04-06; accessed 2026-09-04
Capacity test (DC)
Average test load: unknown
test date unknown
670 Wh
87%
691 Wh-21 Wh (-3%)HoboTech EcoFlow River 2 Pro review
2023-04-06; accessed 2026-09-04

Runtime estimate

Formula starting points use each scenario’s default watts, duty cycle and output path, with 10% reserve or 15% for CPAP. Linked detail pages use the same inputs. Hours apply only if the device can run and start; they are not measured runtimes.

Swipe table sideways
Runtime estimate
Device scenarioPlanning defaultEstimated runtimeDevice scenario: ConfidenceModels
Full-size refrigerator500 W · 33% · AC inverter · Reserve: 10%3h 34m
Exceeds a tracked power limit — do not rely on these hours
EstimatedOpen estimate
CPAP without heated humidifier40 W · 100% · AC inverter · Reserve: 15%13h 52m
Within the tracked power limits; compatibility still needs checking
EstimatedOpen estimate
Starlink Mini32 W · 100% · USB-C PD · Reserve: 10%19h 52m
Within the tracked power limits; compatibility still needs checking
EstimatedOpen estimate
Wi-Fi router12 W · 100% · AC inverter · Reserve: 10%2d 2h
Within the tracked power limits; compatibility still needs checking
EstimatedOpen estimate
LED TV100 W · 100% · AC inverter · Reserve: 10%5h 53m
Within the tracked power limits; compatibility still needs checking
EstimatedOpen estimate

Runtime calculator

Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

Loading calculatorPreparing calculator
Power station model
Battery capacity (Wh): 768 WhContinuous output rating (W): 800 WSurge output rating (W): 1600 W
EcoFlow RIVER 2 Pro
Estimated runtime9h 48m6h 8m – 12h 10mEstimated runtime: 9h 48m, 6h 8m – 12h 10m
Output path

Estimated runtime

Within the tracked power limits; compatibility still needs checking

This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

9h 48mEstimated runtime: 9h 48m

This setup may cover a partial outage or single overnight session. Add capacity for more margin.

Conservative6h 8m
Estimated9h 48m
Optimistic12h 10m

These are calculated sensitivity cases, not a statistical confidence interval. Conservative uses lower efficiency and battery health, more reserve/temperature loss and higher load; optimistic changes these assumptions in the opposite direction.

  • This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.
  • Within the tracked power limits; compatibility still needs checking

Show your work

Rated Wh is reduced by efficiency, reserve, battery health, and temperature before it is divided by average load.

Rated battery
768 Wh
Usable energy
588 Wh
768 Wh x 85% x 90% x 100% x 100%
Running watts
60 W
Average load
60 W
Max surge
n/a
Fixed station overhead
Unknown (not included)
60 W / 85% = 70.6 W battery draw; fixed overhead is unknown and excluded
Estimated runtime
9h 48m
588 Wh / 60 W = 9h 48m
Output path
AC inverter
Efficiency (%)
85
Reserve kept unused (%)
10
Battery health (%)
100
Cold weather loss (%)
0

This link contains the numeric values you entered, but not custom load names.

Source-Backed Next Steps

Planning notes

  • Capacity class: 768 Wh. Size the battery for your measured average load and required hours, including reserve.
  • Tracked output: 800 W. Compare both running demand and startup demand before using any runtime estimate.
  • Solar input limit: 220 W. Actual refill depends on panel voltage/current compatibility, sunlight, angle and charging losses.

Known data gaps

  • Unverified or missing specifications remain visible. The confidence label describes the station record, not a tested runtime or approval for emergency use.
  • Weight: 8.25 kg. Check the complete carrying setup, cables and battery extensions before choosing this model for travel.
  • unknown: —

Models: EcoFlow

Compare nearby capacity records from the same brand, then check output, weight and missing fields. A larger battery does not establish device compatibility.

Specification comparison

Use these as planning shortcuts, then confirm the full table and sources.

Sources