EcoFlow RIVER Pro Runtime Calculator

Quick answer: the EcoFlow RIVER Pro stores 720 Wh and delivers up to 600 W of continuous AC power. Under this site's planning assumptions (85% inverter efficiency, 10% reserve), a steady 100 W AC load runs for roughly 5.5 hours. Last source check: 2026-08-27. This is an estimate, not a guarantee.

EcoFlow RIVER Pro portable power station
Battery capacity720 Wh
AC output600 W
Surge output1,200 W
Battery chemistryLi-ion
ConfidenceEstimated
Source regionGlobal/general sources
checked2026-08-27
Swipe table sideways
EcoFlow RIVER Pro: Key facts
Battery capacity720 Wh
Battery chemistryLi-ion
AC output600 W
Surge output1,200 W
DC output136 W
USB-C output100 W
Solar input200 W
Weightunknown
ConfidenceEstimated
Lifecycle statusUnknown
Source regionGlobal/general sources
Last verified2026-08-27
Catalog notes (original English)

EcoFlow's own storefront no longer lists this discontinued model, so this record uses a retailer-published copy of the manufacturer specification table. Weight stays unknown because the table publishes none.

Runtime estimate

Formula starting points use each scenario’s default watts, duty cycle and output path, with 10% reserve or 15% for CPAP. Linked detail pages use the same inputs. Hours apply only if the device can run and start; they are not measured runtimes.

Swipe table sideways
Runtime estimate
Device scenarioPlanning defaultEstimated runtimeDevice scenario: ConfidenceModels
Full-size refrigerator500 W · 33% · AC inverter · Reserve: 10%3h 20m
Exceeds a tracked power limit — do not rely on these hours
EstimatedCalculator
CPAP without heated humidifier40 W · 100% · AC inverter · Reserve: 15%13h 0m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
Starlink Mini32 W · 100% · USB-C PD · Reserve: 10%18h 38m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
Wi-Fi router12 W · 100% · AC inverter · Reserve: 10%1d 23h
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
LED TV100 W · 100% · AC inverter · Reserve: 10%5h 30m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator

Runtime calculator

Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

Loading calculatorPreparing calculator
Power station model
Battery capacity (Wh): 720 WhContinuous output rating (W): 600 WSurge output rating (W): 1200 W
EcoFlow RIVER Pro
Estimated runtime9h 11m5h 45m – 11h 24mEstimated runtime: 9h 11m, 5h 45m – 11h 24m
Output path

Estimated runtime

Within the tracked power limits; compatibility still needs checking

This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

9h 11mEstimated runtime: 9h 11m

This setup may cover a partial outage or single overnight session. Add capacity for more margin.

Conservative5h 45m
Estimated9h 11m
Optimistic11h 24m

These are calculated sensitivity cases, not a statistical confidence interval. Conservative uses lower efficiency and battery health, more reserve/temperature loss and higher load; optimistic changes these assumptions in the opposite direction.

  • This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.
  • Within the tracked power limits; compatibility still needs checking

Show your work

Rated Wh is reduced by efficiency, reserve, battery health, and temperature before it is divided by average load.

Rated battery
720 Wh
Usable energy
551 Wh
720 Wh x 85% x 90% x 100% x 100%
Running watts
60 W
Average load
60 W
Max surge
n/a
Fixed station overhead
Unknown (not included)
60 W / 85% = 70.6 W battery draw; fixed overhead is unknown and excluded
Estimated runtime
9h 11m
551 Wh / 60 W = 9h 11m
Output path
AC inverter
Efficiency (%)
85
Reserve kept unused (%)
10
Battery health (%)
100
Cold weather loss (%)
0

This link contains the numeric values you entered, but not custom load names.

Source-Backed Next Steps

Planning notes

  • Capacity class: 720 Wh. Size the battery for your measured average load and required hours, including reserve.
  • Tracked output: 600 W. Compare both running demand and startup demand before using any runtime estimate.
  • Solar input limit: 200 W. Actual refill depends on panel voltage/current compatibility, sunlight, angle and charging losses.

Known data gaps

  • Unverified or missing specifications remain visible. The confidence label describes the station record, not a tested runtime or approval for emergency use.
  • Weight: unknown. Check the complete carrying setup, cables and battery extensions before choosing this model for travel.
  • unknown: Weight

Models: EcoFlow

Compare nearby capacity records from the same brand, then check output, weight and missing fields. A larger battery does not establish device compatibility.

Sources