VigorPool Lake 300 Runtime Calculator

Quick answer: the VigorPool Lake 300 stores 320 Wh and delivers up to 300 W of continuous AC power. Under this site's planning assumptions (85% inverter efficiency, 10% reserve), a steady 100 W AC load runs for roughly 2.4 hours. Last source check: 2026-08-26. This is an estimate, not a guarantee.

Battery capacity320 Wh
AC output300 W
Surge output500 W
Battery chemistryLFP (lithium ferrophosphate)
ConfidenceEstimated
Source regionGlobal/general sources
checked2026-08-26
Swipe table sideways
VigorPool Lake 300: Key facts
Battery capacity320 Wh
Battery chemistryLFP (lithium ferrophosphate)
AC output300 W
Surge output500 W
DC outputunknown
USB-C outputunknown
Solar inputunknown
Weight4.3 kg
ConfidenceEstimated
Lifecycle statusUnknown
Source regionGlobal/general sources
Last verified2026-08-26

Runtime estimate

Formula starting points use each scenario’s default watts, duty cycle and output path, with 10% reserve or 15% for CPAP. Linked detail pages use the same inputs. Hours apply only if the device can run and start; they are not measured runtimes.

Swipe table sideways
Runtime estimate
Device scenarioPlanning defaultEstimated runtimeDevice scenario: ConfidenceModels
Full-size refrigerator500 W · 33% · AC inverter · Reserve: 10%1h 29m
Exceeds a tracked power limit — do not rely on these hours
EstimatedCalculator
CPAP without heated humidifier40 W · 100% · AC inverter · Reserve: 15%5h 47m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
Starlink Mini32 W · 100% · USB-C PD · Reserve: 10%8h 17m
Output or startup compatibility is not established
EstimatedCalculator
Wi-Fi router12 W · 100% · AC inverter · Reserve: 10%21h 7m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
LED TV100 W · 100% · AC inverter · Reserve: 10%2h 27m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator

Runtime calculator

Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

Loading calculatorPreparing calculator
Power station model
Battery capacity (Wh): 320 WhContinuous output rating (W): 300 WSurge output rating (W): 500 W
Estimated runtime4h 5m2h 33m – 5h 4mEstimated runtime: 4h 5m, 2h 33m – 5h 4m
Output path

Estimated runtime

Within the tracked power limits; compatibility still needs checking

This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

4h 5mEstimated runtime: 4h 5m

This setup is tight. Reduce load, use DC where possible, or choose a larger station.

Conservative2h 33m
Estimated4h 5m
Optimistic5h 4m

These are calculated sensitivity cases, not a statistical confidence interval. Conservative uses lower efficiency and battery health, more reserve/temperature loss and higher load; optimistic changes these assumptions in the opposite direction.

  • This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.
  • Within the tracked power limits; compatibility still needs checking

Show your work

Rated Wh is reduced by efficiency, reserve, battery health, and temperature before it is divided by average load.

Rated battery
320 Wh
Usable energy
245 Wh
320 Wh x 85% x 90% x 100% x 100%
Running watts
60 W
Average load
60 W
Max surge
n/a
Fixed station overhead
Unknown (not included)
60 W / 85% = 70.6 W battery draw; fixed overhead is unknown and excluded
Estimated runtime
4h 5m
245 Wh / 60 W = 4h 5m
Output path
AC inverter
Efficiency (%)
85
Reserve kept unused (%)
10
Battery health (%)
100
Cold weather loss (%)
0

This link contains the numeric values you entered, but not custom load names.

Source-Backed Next Steps

Planning notes

  • Capacity class: 320 Wh. Size the battery for your measured average load and required hours, including reserve.
  • Tracked output: 300 W. Compare both running demand and startup demand before using any runtime estimate.
  • Solar input limit: unknown. Actual refill depends on panel voltage/current compatibility, sunlight, angle and charging losses.

Known data gaps

  • Unverified or missing specifications remain visible. The confidence label describes the station record, not a tested runtime or approval for emergency use.
  • Weight: 4.3 kg. Check the complete carrying setup, cables and battery extensions before choosing this model for travel.
  • unknown: DC output, USB-C output, Solar input

Models: VigorPool

Compare nearby capacity records from the same brand, then check output, weight and missing fields. A larger battery does not establish device compatibility.

Sources