VigorPool Captain 700 Runtime Calculator

Quick answer: the VigorPool Captain 700 stores 672 Wh and delivers up to 700 W of continuous AC power. Under this site's planning assumptions (85% inverter efficiency, 10% reserve), a steady 100 W AC load runs for roughly 5.1 hours. Last source check: 2026-08-26. This is an estimate, not a guarantee.

Battery capacity672 Wh
AC output700 W
Surge output1,300 W
Battery chemistryLFP (lithium ferrophosphate)
ConfidenceEstimated
Source regionGlobal/general sources
checked2026-08-26
Swipe table sideways
VigorPool Captain 700: Key facts
Battery capacity672 Wh
Battery chemistryLFP (lithium ferrophosphate)
AC output700 W
Surge output1,300 W
DC output120 W
USB-C output60 W
Solar input240 W
Weight9 kg
ConfidenceEstimated
Lifecycle statusUnknown
Source regionGlobal/general sources
Last verified2026-08-26

Runtime estimate

Formula starting points use each scenario’s default watts, duty cycle and output path, with 10% reserve or 15% for CPAP. Linked detail pages use the same inputs. Hours apply only if the device can run and start; they are not measured runtimes.

Swipe table sideways
Runtime estimate
Device scenarioPlanning defaultEstimated runtimeDevice scenario: ConfidenceModels
Full-size refrigerator500 W · 33% · AC inverter · Reserve: 10%3h 7m
Exceeds a tracked power limit — do not rely on these hours
EstimatedCalculator
CPAP without heated humidifier40 W · 100% · AC inverter · Reserve: 15%12h 8m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
Starlink Mini32 W · 100% · USB-C PD · Reserve: 10%17h 23m
Exceeds a tracked power limit — do not rely on these hours
EstimatedCalculator
Wi-Fi router12 W · 100% · AC inverter · Reserve: 10%1d 20h
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
LED TV100 W · 100% · AC inverter · Reserve: 10%5h 8m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator

Runtime calculator

Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

Loading calculatorPreparing calculator
Power station model
Battery capacity (Wh): 672 WhContinuous output rating (W): 700 WSurge output rating (W): 1300 W
Estimated runtime8h 34m5h 22m – 10h 38mEstimated runtime: 8h 34m, 5h 22m – 10h 38m
Output path

Estimated runtime

Within the tracked power limits; compatibility still needs checking

This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

8h 34mEstimated runtime: 8h 34m

This setup may cover a partial outage or single overnight session. Add capacity for more margin.

Conservative5h 22m
Estimated8h 34m
Optimistic10h 38m

These are calculated sensitivity cases, not a statistical confidence interval. Conservative uses lower efficiency and battery health, more reserve/temperature loss and higher load; optimistic changes these assumptions in the opposite direction.

  • This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.
  • Within the tracked power limits; compatibility still needs checking

Show your work

Rated Wh is reduced by efficiency, reserve, battery health, and temperature before it is divided by average load.

Rated battery
672 Wh
Usable energy
514 Wh
672 Wh x 85% x 90% x 100% x 100%
Running watts
60 W
Average load
60 W
Max surge
n/a
Fixed station overhead
Unknown (not included)
60 W / 85% = 70.6 W battery draw; fixed overhead is unknown and excluded
Estimated runtime
8h 34m
514 Wh / 60 W = 8h 34m
Output path
AC inverter
Efficiency (%)
85
Reserve kept unused (%)
10
Battery health (%)
100
Cold weather loss (%)
0

This link contains the numeric values you entered, but not custom load names.

Source-Backed Next Steps

Planning notes

  • Capacity class: 672 Wh. Size the battery for your measured average load and required hours, including reserve.
  • Tracked output: 700 W. Compare both running demand and startup demand before using any runtime estimate.
  • Solar input limit: 240 W. Actual refill depends on panel voltage/current compatibility, sunlight, angle and charging losses.

Known data gaps

  • Unverified or missing specifications remain visible. The confidence label describes the station record, not a tested runtime or approval for emergency use.
  • Weight: 9 kg. Check the complete carrying setup, cables and battery extensions before choosing this model for travel.
  • unknown: —

Models: VigorPool

Compare nearby capacity records from the same brand, then check output, weight and missing fields. A larger battery does not establish device compatibility.

Sources