Renogy Lycan 5000 Runtime Calculator

Quick answer: the Renogy Lycan 5000 stores 4,800 Wh and delivers up to 3,500 W of continuous AC power. Under this site's planning assumptions (85% inverter efficiency, 10% reserve), a steady 100 W AC load runs for roughly 36.7 hours. Last source check: 2026-07-10. This is an estimate, not a guarantee.

Renogy Lycan 5000 portable power station
Battery capacity4,800 Wh
AC output3,500 W
Surge output7,000 W
Battery chemistryLiFePO4
ConfidenceEstimated
Source regionGlobal/general sources
checked2026-07-10
Swipe table sideways
Renogy Lycan 5000: Key facts
Battery capacity4,800 Wh
Battery chemistryLiFePO4
AC output3,500 W
Surge output7,000 W
DC outputunknown
USB-C outputunknown
Solar input4,400 W
Weight120 kg
ConfidenceEstimated
Lifecycle statusUnknown
Source regionGlobal/general sources
Last verified2026-07-10
Catalog notes (original English)

Solar input uses the official 4400W maximum. DC and USB-C output ceilings remain unknown because the checked official sources do not publish them.

Runtime estimate

Formula starting points use each scenario’s default watts, duty cycle and output path, with 10% reserve or 15% for CPAP. Linked detail pages use the same inputs. Hours apply only if the device can run and start; they are not measured runtimes.

Swipe table sideways
Runtime estimate
Device scenarioPlanning defaultEstimated runtimeDevice scenario: ConfidenceModels
Full-size refrigerator500 W · 33% · AC inverter · Reserve: 10%22h 15m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
CPAP without heated humidifier40 W · 100% · AC inverter · Reserve: 15%3d 14h
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
Starlink Mini32 W · 100% · USB-C PD · Reserve: 10%5d 4h
Output or startup compatibility is not established
EstimatedCalculator
Wi-Fi router12 W · 100% · AC inverter · Reserve: 10%13d 4h
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
LED TV100 W · 100% · AC inverter · Reserve: 10%1d 12h
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator

Runtime calculator

Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

Loading calculatorPreparing calculator
Power station model
Battery capacity (Wh): 4800 WhContinuous output rating (W): 3500 WSurge output rating (W): 7000 W
Renogy Lycan 5000
Estimated runtime2d 13h1d 14h – 3d 4hEstimated runtime: 2d 13h, 1d 14h – 3d 4h
Output path

Estimated runtime

Within the tracked power limits; compatibility still needs checking

This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

2d 13hEstimated runtime: 2d 13h

This setup has comfortable headroom for overnight use, assuming the wattage estimate is realistic.

Conservative1d 14h
Estimated2d 13h
Optimistic3d 4h

These are calculated sensitivity cases, not a statistical confidence interval. Conservative uses lower efficiency and battery health, more reserve/temperature loss and higher load; optimistic changes these assumptions in the opposite direction.

  • This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.
  • Within the tracked power limits; compatibility still needs checking

Show your work

Rated Wh is reduced by efficiency, reserve, battery health, and temperature before it is divided by average load.

Rated battery
4800 Wh
Usable energy
3672 Wh
4800 Wh x 85% x 90% x 100% x 100%
Running watts
60 W
Average load
60 W
Max surge
n/a
Fixed station overhead
Unknown (not included)
60 W / 85% = 70.6 W battery draw; fixed overhead is unknown and excluded
Estimated runtime
2d 13h
3672 Wh / 60 W = 2d 13h
Output path
AC inverter
Efficiency (%)
85
Reserve kept unused (%)
10
Battery health (%)
100
Cold weather loss (%)
0

This link contains the numeric values you entered, but not custom load names.

Source-Backed Next Steps

Planning notes

  • Capacity class: 4,800 Wh. Size the battery for your measured average load and required hours, including reserve.
  • Tracked output: 3,500 W. Compare both running demand and startup demand before using any runtime estimate.
  • Solar input limit: 4,400 W. Actual refill depends on panel voltage/current compatibility, sunlight, angle and charging losses.

Known data gaps

  • Unverified or missing specifications remain visible. The confidence label describes the station record, not a tested runtime or approval for emergency use.
  • Weight: 120 kg. Check the complete carrying setup, cables and battery extensions before choosing this model for travel.
  • unknown: DC output, USB-C output

Models: Renogy

Compare nearby capacity records from the same brand, then check output, weight and missing fields. A larger battery does not establish device compatibility.

Sources