Inergy Flex 1500 TL Runtime Calculator

Quick answer: the Inergy Flex 1500 TL stores 1,000 Wh and delivers up to 1,500 W of continuous AC power. Under this site's planning assumptions (85% inverter efficiency, 10% reserve), a steady 100 W AC load runs for roughly 7.7 hours. Last source check: 2026-08-27. This is an estimate, not a guarantee.

Inergy Flex 1500 TL portable power station
Battery capacity1,000 Wh
AC output1,500 W
Surge output3,000 W
Battery chemistryLi-ion NMC
ConfidenceEstimated
Source regionGlobal/general sources
checked2026-08-27
Swipe table sideways
Inergy Flex 1500 TL: Key facts
Battery capacity1,000 Wh
Battery chemistryLi-ion NMC
AC output1,500 W
Surge output3,000 W
DC outputunknown
USB-C output60 W
Solar inputunknown
Weightunknown
ConfidenceEstimated
Lifecycle statusUnknown
Source regionGlobal/general sources
Last verified2026-08-27
Catalog notes (original English)

Solar input stays unknown because the page publishes a voltage window and a charge-current limit rather than a watt ceiling; DC stays unknown for the same reason. Weight is not published on this listing.

Runtime estimate

Formula starting points use each scenario’s default watts, duty cycle and output path, with 10% reserve or 15% for CPAP. Linked detail pages use the same inputs. Hours apply only if the device can run and start; they are not measured runtimes.

Swipe table sideways
Runtime estimate
Device scenarioPlanning defaultEstimated runtimeDevice scenario: ConfidenceModels
Full-size refrigerator500 W · 33% · AC inverter · Reserve: 10%4h 38m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
CPAP without heated humidifier40 W · 100% · AC inverter · Reserve: 15%18h 4m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
Starlink Mini32 W · 100% · USB-C PD · Reserve: 10%1d 1h
Exceeds a tracked power limit — do not rely on these hours
EstimatedCalculator
Wi-Fi router12 W · 100% · AC inverter · Reserve: 10%2d 18h
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
LED TV100 W · 100% · AC inverter · Reserve: 10%7h 39m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator

Runtime calculator

Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

Loading calculatorPreparing calculator
Power station model
Battery capacity (Wh): 1000 WhContinuous output rating (W): 1500 WSurge output rating (W): 3000 W
Inergy Flex 1500 TL
Estimated runtime12h 45m7h 59m – 15h 50mEstimated runtime: 12h 45m, 7h 59m – 15h 50m
Output path

Estimated runtime

Within the tracked power limits; compatibility still needs checking

This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

12h 45mEstimated runtime: 12h 45m

This setup has comfortable headroom for overnight use, assuming the wattage estimate is realistic.

Conservative7h 59m
Estimated12h 45m
Optimistic15h 50m

These are calculated sensitivity cases, not a statistical confidence interval. Conservative uses lower efficiency and battery health, more reserve/temperature loss and higher load; optimistic changes these assumptions in the opposite direction.

  • This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.
  • Within the tracked power limits; compatibility still needs checking

Show your work

Rated Wh is reduced by efficiency, reserve, battery health, and temperature before it is divided by average load.

Rated battery
1000 Wh
Usable energy
765 Wh
1000 Wh x 85% x 90% x 100% x 100%
Running watts
60 W
Average load
60 W
Max surge
n/a
Fixed station overhead
Unknown (not included)
60 W / 85% = 70.6 W battery draw; fixed overhead is unknown and excluded
Estimated runtime
12h 45m
765 Wh / 60 W = 12h 45m
Output path
AC inverter
Efficiency (%)
85
Reserve kept unused (%)
10
Battery health (%)
100
Cold weather loss (%)
0

This link contains the numeric values you entered, but not custom load names.

Source-Backed Next Steps

Planning notes

  • Capacity class: 1,000 Wh. Size the battery for your measured average load and required hours, including reserve.
  • Tracked output: 1,500 W. Compare both running demand and startup demand before using any runtime estimate.
  • Solar input limit: unknown. Actual refill depends on panel voltage/current compatibility, sunlight, angle and charging losses.

Known data gaps

  • Unverified or missing specifications remain visible. The confidence label describes the station record, not a tested runtime or approval for emergency use.
  • Weight: unknown. Check the complete carrying setup, cables and battery extensions before choosing this model for travel.
  • unknown: DC output, Solar input, Weight

Models: Inergy

Compare nearby capacity records from the same brand, then check output, weight and missing fields. A larger battery does not establish device compatibility.

Inergy Kodiak

1,100 Wh · AC output: 1,500 W · Confidence: Estimated

Sources