Hysolis MPS3K Runtime Calculator

Quick answer: the Hysolis MPS3K stores 4,500 Wh and delivers up to 3,000 W of continuous AC power. Under this site's planning assumptions (85% inverter efficiency, 10% reserve), a steady 100 W AC load runs for roughly 34.4 hours. Last source check: 2026-08-21. This is an estimate, not a guarantee.

Hysolis MPS3K portable power station
Battery capacity4,500 Wh
AC output3,000 W
Surge output6,000 W
Battery chemistryLithium-ion (NCM)
ConfidenceVerified
Source regionGlobal/general sources
checked2026-08-21
Swipe table sideways
Hysolis MPS3K: Key facts
Battery capacity4,500 Wh
Battery chemistryLithium-ion (NCM)
AC output3,000 W
Surge output6,000 W
DC output240 W
USB-C output60 W
Solar input1,500 W
Weight55 kg
ConfidenceVerified
Lifecycle statusUnknown
Source regionGlobal/general sources
Last verified2026-08-21
Catalog notes (original English)

DC stores the highest explicit single path, the 240W 12V/20A output; lower-power 12V sockets are not summed. The 60W USB-C value is published directly by the manual. The formal charging table says default 1kW adjustable 0-1kW while nearby marketing copy says 1,200W AC charging; charging-input power is not modeled here.

Runtime estimate

Formula starting points use each scenario’s default watts, duty cycle and output path, with 10% reserve or 15% for CPAP. Linked detail pages use the same inputs. Hours apply only if the device can run and start; they are not measured runtimes.

Swipe table sideways
Runtime estimate
Device scenarioPlanning defaultEstimated runtimeDevice scenario: ConfidenceModels
Full-size refrigerator500 W · 33% · AC inverter · Reserve: 10%20h 52m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
CPAP without heated humidifier40 W · 100% · AC inverter · Reserve: 15%3d 9h
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
Starlink Mini32 W · 100% · USB-C PD · Reserve: 10%4d 20h
Exceeds a tracked power limit — do not rely on these hours
EstimatedCalculator
Wi-Fi router12 W · 100% · AC inverter · Reserve: 10%12d 9h
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
LED TV100 W · 100% · AC inverter · Reserve: 10%1d 10h
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator

Runtime calculator

Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

Loading calculatorPreparing calculator
Power station model
Battery capacity (Wh): 4500 WhContinuous output rating (W): 3000 WSurge output rating (W): 6000 W
Hysolis MPS3K
Estimated runtime2d 9h1d 11h – 2d 23hEstimated runtime: 2d 9h, 1d 11h – 2d 23h
Output path

Estimated runtime

Within the tracked power limits; compatibility still needs checking

This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

2d 9hEstimated runtime: 2d 9h

This setup has comfortable headroom for overnight use, assuming the wattage estimate is realistic.

Conservative1d 11h
Estimated2d 9h
Optimistic2d 23h

These are calculated sensitivity cases, not a statistical confidence interval. Conservative uses lower efficiency and battery health, more reserve/temperature loss and higher load; optimistic changes these assumptions in the opposite direction.

  • This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.
  • Within the tracked power limits; compatibility still needs checking

Show your work

Rated Wh is reduced by efficiency, reserve, battery health, and temperature before it is divided by average load.

Rated battery
4500 Wh
Usable energy
3443 Wh
4500 Wh x 85% x 90% x 100% x 100%
Running watts
60 W
Average load
60 W
Max surge
n/a
Fixed station overhead
Unknown (not included)
60 W / 85% = 70.6 W battery draw; fixed overhead is unknown and excluded
Estimated runtime
2d 9h
3443 Wh / 60 W = 2d 9h
Output path
AC inverter
Efficiency (%)
85
Reserve kept unused (%)
10
Battery health (%)
100
Cold weather loss (%)
0

This link contains the numeric values you entered, but not custom load names.

Source-Backed Next Steps

Planning notes

  • Capacity class: 4,500 Wh. Size the battery for your measured average load and required hours, including reserve.
  • Tracked output: 3,000 W. Compare both running demand and startup demand before using any runtime estimate.
  • Solar input limit: 1,500 W. Actual refill depends on panel voltage/current compatibility, sunlight, angle and charging losses.

Known data gaps

  • Unverified or missing specifications remain visible. The confidence label describes the station record, not a tested runtime or approval for emergency use.
  • Weight: 55 kg. Check the complete carrying setup, cables and battery extensions before choosing this model for travel.
  • unknown: —

Models: Hysolis

Compare nearby capacity records from the same brand, then check output, weight and missing fields. A larger battery does not establish device compatibility.