Hysolis Apollo 5K Runtime Calculator

Quick answer: the Hysolis Apollo 5K stores 5,376 Wh and delivers up to 3,000 W of continuous AC power. Under this site's planning assumptions (85% inverter efficiency, 10% reserve), a steady 100 W AC load runs for roughly 41.1 hours. Last source check: 2026-08-21. This is an estimate, not a guarantee.

Hysolis Apollo 5K portable power station
Battery capacity5,376 Wh
AC output3,000 W
Surge output6,000 W
Battery chemistryLiFePO4
ConfidenceVerified
Source regionGlobal/general sources
checked2026-08-21
Swipe table sideways
Hysolis Apollo 5K: Key facts
Battery capacity5,376 Wh
Battery chemistryLiFePO4
AC output3,000 W
Surge output6,000 W
DC output360 W
USB-C output100 W
Solar input4,400 W
Weight59.5 kg
ConfidenceVerified
Lifecycle statusUnknown
Source regionGlobal/general sources
Last verified2026-08-21
Catalog notes (original English)

This record models one Apollo 5K base station only: multi-unit AC ratings and expansion-battery capacities are excluded. DC stores the highest explicit single path, the 360W Anderson output; USB-C stores the manual's 100W single-port ceiling. Solar input uses the formal 4,400W charger rating, not the separate 5,000W inversion-plus-charge system ceiling.

Runtime estimate

Formula starting points use each scenario’s default watts, duty cycle and output path, with 10% reserve or 15% for CPAP. Linked detail pages use the same inputs. Hours apply only if the device can run and start; they are not measured runtimes.

Swipe table sideways
Runtime estimate
Device scenarioPlanning defaultEstimated runtimeDevice scenario: ConfidenceModels
Full-size refrigerator500 W · 33% · AC inverter · Reserve: 10%1d 0h
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
CPAP without heated humidifier40 W · 100% · AC inverter · Reserve: 15%4d 1h
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
Starlink Mini32 W · 100% · USB-C PD · Reserve: 10%5d 19h
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
Wi-Fi router12 W · 100% · AC inverter · Reserve: 10%14d 18h
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
LED TV100 W · 100% · AC inverter · Reserve: 10%1d 17h
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator

Runtime calculator

Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

Loading calculatorPreparing calculator
Power station model
Battery capacity (Wh): 5376 WhContinuous output rating (W): 3000 WSurge output rating (W): 6000 W
Hysolis Apollo 5K
Estimated runtime2d 20h1d 18h – 3d 13hEstimated runtime: 2d 20h, 1d 18h – 3d 13h
Output path

Estimated runtime

Within the tracked power limits; compatibility still needs checking

This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

2d 20hEstimated runtime: 2d 20h

This setup has comfortable headroom for overnight use, assuming the wattage estimate is realistic.

Conservative1d 18h
Estimated2d 20h
Optimistic3d 13h

These are calculated sensitivity cases, not a statistical confidence interval. Conservative uses lower efficiency and battery health, more reserve/temperature loss and higher load; optimistic changes these assumptions in the opposite direction.

  • This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.
  • Within the tracked power limits; compatibility still needs checking

Show your work

Rated Wh is reduced by efficiency, reserve, battery health, and temperature before it is divided by average load.

Rated battery
5376 Wh
Usable energy
4113 Wh
5376 Wh x 85% x 90% x 100% x 100%
Running watts
60 W
Average load
60 W
Max surge
n/a
Fixed station overhead
Unknown (not included)
60 W / 85% = 70.6 W battery draw; fixed overhead is unknown and excluded
Estimated runtime
2d 20h
4113 Wh / 60 W = 2d 20h
Output path
AC inverter
Efficiency (%)
85
Reserve kept unused (%)
10
Battery health (%)
100
Cold weather loss (%)
0

This link contains the numeric values you entered, but not custom load names.

Source-Backed Next Steps

Planning notes

  • Capacity class: 5,376 Wh. Size the battery for your measured average load and required hours, including reserve.
  • Tracked output: 3,000 W. Compare both running demand and startup demand before using any runtime estimate.
  • Solar input limit: 4,400 W. Actual refill depends on panel voltage/current compatibility, sunlight, angle and charging losses.

Known data gaps

  • Unverified or missing specifications remain visible. The confidence label describes the station record, not a tested runtime or approval for emergency use.
  • Weight: 59.5 kg. Check the complete carrying setup, cables and battery extensions before choosing this model for travel.
  • unknown: —

Models: Hysolis

Compare nearby capacity records from the same brand, then check output, weight and missing fields. A larger battery does not establish device compatibility.

Hysolis MPS3K

4,500 Wh · AC output: 3,000 W · Confidence: Verified

Sources