Menu
Source-linked model
EcoFlow DELTA Pro Runtime Calculator
Use this source-linked record to estimate runtime from tracked capacity, output, charging, and weight fields. Unknown specs stay unknown until an official or manufacturer-grade source confirms them.

| Battery capacity | 3600 Wh |
|---|---|
| Battery chemistry | LFP |
| AC output | 3,600 W |
| Surge output | 7,200 W |
| DC output | 126 W |
| USB-C output | 100 W |
| Solar input | 1,600 W |
| Weight | 45 kg |
| Confidence | Verified |
| Lifecycle status | Unknown |
| Source region | US |
| Last verified | 2026-06-24 |
Third-party measured tests
These are published third-party measurements for this model. The delta compares measured delivered Wh with WattRunTime's default no-reserve planning estimate for the same output path; it is not a new measurement.
| Test | Measured | Default estimate | Vs estimate | Source |
|---|---|---|---|---|
| Capacity test (AC) test date unknown | 2,950 Wh 82% usable | 3,060 Wh | -110 Wh (-4%) | OutdoorGearLab Best Power Stations of 2026 accessed 2026-07-02 |
Runtime Starting Points
These are formula estimates using the tracked capacity, a 10% reserve, and each scenario's default wattage and duty cycle. They are planning starters, not measured runtimes.
| Scenario | Default load | Estimate | Scenario confidence | Station page |
|---|---|---|---|---|
| Full-size refrigerator | 500 W at 33% | 16h 41m | Estimated | Open estimate |
| CPAP without heated humidifier | 40 W at 100% | 2d 20h | Estimated | Open estimate |
| Starlink Mini | 32 W at 100% | 3d 19h | Estimated | Open estimate |
| Wi-Fi router | 12 W at 100% | 9d 21h | Estimated | Open estimate |
| LED TV | 100 W at 100% | 1d 3h | Estimated | Open estimate |
Calculator for this station
Adjust watts, duty cycle, reserve, output path, and startup surge with EcoFlow DELTA Pro prefilled from the source-linked specs above.
Something blocked the calculator from starting. Check your connection or reload the page to try again.

Estimated runtime
1d 21hEstimated runtime: 1d 21hThis setup has comfortable headroom for overnight use, assuming the wattage estimate is realistic.
Conservative assumes harder conditions; optimistic assumes favorable conditions.
- This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior.
- Usable energy
- 2754 Wh
- Average load
- 60 W
- Fixed station overhead
- Unknown (not included)
- Running watts
- 60 W
- Max surge
- n/a
Show your work
Rated Wh is reduced by efficiency, reserve, battery health, and temperature before it is divided by average load.
- Rated battery
- 3600 Wh
- Battery capacity (Wh): 3600 Wh
- Usable energy
- 2754 Wh
- 3600 Wh x 85% x 90% x 100% x 100%
- Average load
- 60 W
- 60 W running, 60 W average after duty cycle and quantity
- Fixed station overhead
- Unknown (not included)
- 60 W / 85% = 70.6 W battery draw; fixed overhead is unknown and excluded
- Estimated runtime
- 1d 21h
- 2754 Wh / 60 W = 1d 21h
- 3600 Wh nominal battery capacity
- AC inverter output path
- 85% conversion efficiency
- 10% reserve kept unused
- 60 W average load from 1 load
- 100% battery health
- 0% temperature loss
- Fixed station overhead unknown; not included
This link contains the numeric values you entered, but not custom load names.
WattRunTime.com
WattRunTime estimate
Estimated runtime
1d 21hThis setup has comfortable headroom for overnight use, assuming the wattage estimate is realistic.Runtime range
Show your work
Rated Wh is reduced by efficiency, reserve, battery health, and temperature before it is divided by average load.
Assumptions
- 3600 Wh nominal battery capacity
- AC inverter output path
- 85% conversion efficiency
- 10% reserve kept unused
- 60 W average load from 1 load
- 100% battery health
- 0% temperature loss
- Fixed station overhead unknown; not included
Warnings
- This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior.
Share URL
Good fit when
- Capacity is in a larger outage/RV class, so the useful question is usually output limits, recharge speed, and weight rather than watt-hours alone.
- Tracked AC output is high enough for many household plug-in loads, but surge still needs a separate check.
- USB-C output is tracked at laptop-class power, useful for direct DC charging when the device supports it.
- Tracked solar input is 1,600 W before panel, weather, angle, and controller losses.
Watch out for
- Surge output is tracked, but device startup behavior should still be checked against the actual load.
- Tracked weight is in a heavier class; plan where it will live before treating it as a grab-and-go station.
Related EcoFlow Records
Nearby source-linked models from the same brand help you compare capacity, output, and unknown fields without leaving the data set.
DELTA Pro 3
4,096 Wh, 4,000 W AC output, confidence: Verified.
DELTA 3 Ultra
3,072 Wh, 3,600 W AC output, confidence: Verified.
DELTA 3 Ultra Plus
3,072 Wh, 3,600 W AC output, confidence: Verified.
Compare DELTA Pro With Similar Stations
These source-aware comparisons use the same assumptions on both sides and keep unknown fields visible.
Jackery Explorer 2000 Plus vs EcoFlow DELTA Pro
Compare against Jackery Explorer 2000 Plus by capacity, output, solar input, weight, confidence, and shared runtime examples.
Sources
- EcoFlow DELTA Pro specifications (official; checked 2026-06-24)