EcoFlow DELTA 2 Runtime Calculator

Quick answer: the EcoFlow DELTA 2 stores 1,024 Wh and delivers up to 1,800 W of continuous AC power. Under this site's planning assumptions (85% inverter efficiency, 10% reserve), a steady 100 W AC load runs for roughly 7.8 hours. Last source check: 2026-08-20. This is an estimate, not a guarantee.

EcoFlow DELTA 2 portable power station
Battery capacity1,024 Wh
AC output1,800 W
Surge output2,700 W
Battery chemistryLFP (LiFePO4)
ConfidenceVerified
Source regionGlobal/general sources
checked2026-08-20
Swipe table sideways
EcoFlow DELTA 2: Key facts
Battery capacity1,024 Wh
Battery chemistryLFP (LiFePO4)
AC output1,800 W
Surge output2,700 W
DC output126 W
USB-C output100 W
Solar input500 W
Weight12 kg
ConfidenceVerified
Lifecycle statusUnknown
Source regionGlobal/general sources
Last verified2026-08-20

Measurement Records

Third-party results apply to the listed model, output path and test load. The delta is against a fixed no-reserve planning formula, not an error score or a prediction at other loads. Missing test conditions remain unknown.

Swipe table sideways
Measurement Records: EcoFlow DELTA 2
TestMeasureddefault planning estimateVs estimateSource
Runtime test (AC)
Average test load: ~380 W
test date unknown
900 Wh
88%
870 Wh+30 Wh (+3%)Outdoor Life Best Portable Power Stations of 2026
2026-01-09; accessed 2026-09-04
Runtime test (AC)
Average test load: ~34 W
test date unknown
690 Wh
67%
870 Wh-180 Wh (-21%)Outdoor Life Best Portable Power Stations of 2026
2026-01-09; accessed 2026-09-04

Runtime estimate

Formula starting points use each scenario’s default watts, duty cycle and output path, with 10% reserve or 15% for CPAP. Linked detail pages use the same inputs. Hours apply only if the device can run and start; they are not measured runtimes.

Swipe table sideways
Runtime estimate
Device scenarioPlanning defaultEstimated runtimeDevice scenario: ConfidenceModels
Full-size refrigerator500 W · 33% · AC inverter · Reserve: 10%4h 45m
Exceeds a tracked power limit — do not rely on these hours
EstimatedOpen estimate
CPAP without heated humidifier40 W · 100% · AC inverter · Reserve: 15%18h 30m
Within the tracked power limits; compatibility still needs checking
EstimatedOpen estimate
Starlink Mini32 W · 100% · USB-C PD · Reserve: 10%1d 2h
Within the tracked power limits; compatibility still needs checking
EstimatedOpen estimate
Wi-Fi router12 W · 100% · AC inverter · Reserve: 10%2d 19h
Within the tracked power limits; compatibility still needs checking
EstimatedOpen estimate
LED TV100 W · 100% · AC inverter · Reserve: 10%7h 50m
Within the tracked power limits; compatibility still needs checking
EstimatedOpen estimate

Runtime calculator

Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

Loading calculatorPreparing calculator
Power station model
Battery capacity (Wh): 1024 WhContinuous output rating (W): 1800 WSurge output rating (W): 2700 W
EcoFlow DELTA 2
Estimated runtime13h 3m8h 10m – 16h 13mEstimated runtime: 13h 3m, 8h 10m – 16h 13m
Output path

Estimated runtime

Within the tracked power limits; compatibility still needs checking

This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

13h 3mEstimated runtime: 13h 3m

This setup has comfortable headroom for overnight use, assuming the wattage estimate is realistic.

Conservative8h 10m
Estimated13h 3m
Optimistic16h 13m

These are calculated sensitivity cases, not a statistical confidence interval. Conservative uses lower efficiency and battery health, more reserve/temperature loss and higher load; optimistic changes these assumptions in the opposite direction.

  • This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.
  • Within the tracked power limits; compatibility still needs checking

Show your work

Rated Wh is reduced by efficiency, reserve, battery health, and temperature before it is divided by average load.

Rated battery
1024 Wh
Usable energy
783 Wh
1024 Wh x 85% x 90% x 100% x 100%
Running watts
60 W
Average load
60 W
Max surge
n/a
Fixed station overhead
Unknown (not included)
60 W / 85% = 70.6 W battery draw; fixed overhead is unknown and excluded
Estimated runtime
13h 3m
783 Wh / 60 W = 13h 3m
Output path
AC inverter
Efficiency (%)
85
Reserve kept unused (%)
10
Battery health (%)
100
Cold weather loss (%)
0

This link contains the numeric values you entered, but not custom load names.

Source-Backed Next Steps

Planning notes

  • Capacity class: 1,024 Wh. Size the battery for your measured average load and required hours, including reserve.
  • Tracked output: 1,800 W. Compare both running demand and startup demand before using any runtime estimate.
  • Solar input limit: 500 W. Actual refill depends on panel voltage/current compatibility, sunlight, angle and charging losses.

Known data gaps

  • Unverified or missing specifications remain visible. The confidence label describes the station record, not a tested runtime or approval for emergency use.
  • Weight: 12 kg. Check the complete carrying setup, cables and battery extensions before choosing this model for travel.
  • unknown: —

Models: EcoFlow

Compare nearby capacity records from the same brand, then check output, weight and missing fields. A larger battery does not establish device compatibility.

Specification comparison

Use these as planning shortcuts, then confirm the full table and sources.

Sources