AFERIY P010 Runtime Calculator

Quick answer: the AFERIY P010 stores 512 Wh and delivers up to 800 W of continuous AC power. Under this site's planning assumptions (85% inverter efficiency, 10% reserve), a steady 100 W AC load runs for roughly 3.9 hours. Last source check: 2026-08-21. This is an estimate, not a guarantee.

AFERIY P010 portable power station
Battery capacity512 Wh
AC output800 W
Surge outputunknown
Battery chemistryLiFePO4
ConfidenceEstimated
Source regionGlobal/general sources
checked2026-08-21
Swipe table sideways
AFERIY P010: Key facts
Battery capacity512 Wh
Battery chemistryLiFePO4
AC output800 W
Surge outputunknown
DC output120 W
USB-C output100 W
Solar input200 W
Weight6.5 kg
ConfidenceEstimated
Lifecycle statusUnknown
Source regionGlobal/general sources
Last verified2026-08-21
Catalog notes (original English)

This record follows the US 100-120V P010 configuration. Surge remains unknown: the official FAQ warns that motor startup can demand two to seven times rated power but does not publish the station's surge limit. DC stores one 120W path rather than summing the car and DC6530 ports.

Runtime estimate

Formula starting points use each scenario’s default watts, duty cycle and output path, with 10% reserve or 15% for CPAP. Linked detail pages use the same inputs. Hours apply only if the device can run and start; they are not measured runtimes.

Swipe table sideways
Runtime estimate
Device scenarioPlanning defaultEstimated runtimeDevice scenario: ConfidenceModels
Full-size refrigerator500 W · 33% · AC inverter · Reserve: 10%2h 22m
Output or startup compatibility is not established
EstimatedCalculator
CPAP without heated humidifier40 W · 100% · AC inverter · Reserve: 15%9h 15m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
Starlink Mini32 W · 100% · USB-C PD · Reserve: 10%13h 15m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
Wi-Fi router12 W · 100% · AC inverter · Reserve: 10%1d 9h
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
LED TV100 W · 100% · AC inverter · Reserve: 10%3h 55m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator

Runtime calculator

Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

Loading calculatorPreparing calculator
Power station model
Battery capacity (Wh): 512 WhContinuous output rating (W): 800 WSurge output rating (W): n/a
AFERIY P010
Estimated runtime6h 32m4h 5m – 8h 6mEstimated runtime: 6h 32m, 4h 5m – 8h 6m
Output path

Estimated runtime

Within the tracked power limits; compatibility still needs checking

This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

6h 32mEstimated runtime: 6h 32m

This setup may cover a partial outage or single overnight session. Add capacity for more margin.

Conservative4h 5m
Estimated6h 32m
Optimistic8h 6m

These are calculated sensitivity cases, not a statistical confidence interval. Conservative uses lower efficiency and battery health, more reserve/temperature loss and higher load; optimistic changes these assumptions in the opposite direction.

  • This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.
  • Within the tracked power limits; compatibility still needs checking

Show your work

Rated Wh is reduced by efficiency, reserve, battery health, and temperature before it is divided by average load.

Rated battery
512 Wh
Usable energy
392 Wh
512 Wh x 85% x 90% x 100% x 100%
Running watts
60 W
Average load
60 W
Max surge
n/a
Fixed station overhead
Unknown (not included)
60 W / 85% = 70.6 W battery draw; fixed overhead is unknown and excluded
Estimated runtime
6h 32m
392 Wh / 60 W = 6h 32m
Output path
AC inverter
Efficiency (%)
85
Reserve kept unused (%)
10
Battery health (%)
100
Cold weather loss (%)
0

This link contains the numeric values you entered, but not custom load names.

Source-Backed Next Steps

Planning notes

  • Capacity class: 512 Wh. Size the battery for your measured average load and required hours, including reserve.
  • Tracked output: 800 W. Compare both running demand and startup demand before using any runtime estimate.
  • Solar input limit: 200 W. Actual refill depends on panel voltage/current compatibility, sunlight, angle and charging losses.

Known data gaps

  • Unverified or missing specifications remain visible. The confidence label describes the station record, not a tested runtime or approval for emergency use.
  • Weight: 6.5 kg. Check the complete carrying setup, cables and battery extensions before choosing this model for travel.
  • unknown: Surge output

Models: AFERIY

Compare nearby capacity records from the same brand, then check output, weight and missing fields. A larger battery does not establish device compatibility.

AFERIY P040

256 Wh · AC output: 400 W · Confidence: Verified

AFERIY P110-D

960 Wh · AC output: 1,200 W · Confidence: Verified

Sources