AFERIY Nano100 Runtime Calculator

Quick answer: the AFERIY Nano100 stores 99.2 Wh. Its continuous AC rating is not confirmed by a usable source, so this record keeps the field unknown rather than guessing — check the sources below before planning AC loads. Last source check: 2026-08-21. This is an estimate, not a guarantee.

AFERIY Nano100 portable power station
Battery capacity99.2 Wh
AC outputunknown
Surge outputunknown
Battery chemistryLiFePO4
ConfidenceVerified
Source regionGlobal/general sources
checked2026-08-21
Swipe table sideways
AFERIY Nano100: Key facts
Battery capacity99.2 Wh
Battery chemistryLiFePO4
AC outputunknown
Surge outputunknown
DC outputnot available
USB-C output100 W
Solar input100 W
Weight1.1 kg
ConfidenceVerified
Lifecycle statusUnknown
Source regionGlobal/general sources
Last verified2026-08-21
Catalog notes (original English)

This USB-only station has no AC inverter or conventional 12V output. USB-C stores the 100W highest single-port ceiling rather than the 145W combined two-port total; surge is not applicable when AC output is absent.

Runtime estimate

Formula starting points use each scenario’s default watts, duty cycle and output path, with 10% reserve or 15% for CPAP. Linked detail pages use the same inputs. Hours apply only if the device can run and start; they are not measured runtimes.

Swipe table sideways
Runtime estimate
Device scenarioPlanning defaultEstimated runtimeDevice scenario: ConfidenceModels
Full-size refrigerator500 W · 33% · AC inverter · Reserve: 10%28m
Output or startup compatibility is not established
EstimatedCalculator
CPAP without heated humidifier40 W · 100% · AC inverter · Reserve: 15%1h 48m
Output or startup compatibility is not established
EstimatedCalculator
Starlink Mini32 W · 100% · USB-C PD · Reserve: 10%2h 34m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
Wi-Fi router12 W · 100% · AC inverter · Reserve: 10%6h 33m
Output or startup compatibility is not established
EstimatedCalculator
LED TV100 W · 100% · AC inverter · Reserve: 10%46m
Output or startup compatibility is not established
EstimatedCalculator

Runtime calculator

Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

Loading calculatorPreparing calculator
Power station model
Battery capacity (Wh): 99 WhContinuous output rating (W): n/aSurge output rating (W): n/a
AFERIY Nano100
Estimated runtime1h 16m47m – 1h 34mEstimated runtime: 1h 16m, 47m – 1h 34m
Output path

Estimated runtime

Output or startup compatibility is not established

This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

1h 16mEstimated runtime: 1h 16m

Output or startup compatibility is not established

Conservative47m
Estimated1h 16m
Optimistic1h 34m

These are calculated sensitivity cases, not a statistical confidence interval. Conservative uses lower efficiency and battery health, more reserve/temperature loss and higher load; optimistic changes these assumptions in the opposite direction.

  • This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.
  • Output or startup compatibility is not established
  • The selected station output rating is unknown, so running-load compatibility is not verified.

Show your work

Rated Wh is reduced by efficiency, reserve, battery health, and temperature before it is divided by average load.

Rated battery
99 Wh
Usable energy
76 Wh
99 Wh x 85% x 90% x 100% x 100%
Running watts
60 W
Average load
60 W
Max surge
n/a
Fixed station overhead
Unknown (not included)
60 W / 85% = 70.6 W battery draw; fixed overhead is unknown and excluded
Estimated runtime
1h 16m
76 Wh / 60 W = 1h 16m
Output path
AC inverter
Efficiency (%)
85
Reserve kept unused (%)
10
Battery health (%)
100
Cold weather loss (%)
0

This link contains the numeric values you entered, but not custom load names.

Source-Backed Next Steps

Planning notes

  • Capacity class: 99.2 Wh. Size the battery for your measured average load and required hours, including reserve.
  • Tracked output: unknown. Compare both running demand and startup demand before using any runtime estimate.
  • Solar input limit: 100 W. Actual refill depends on panel voltage/current compatibility, sunlight, angle and charging losses.

Known data gaps

  • Unverified or missing specifications remain visible. The confidence label describes the station record, not a tested runtime or approval for emergency use.
  • Weight: 1.1 kg. Check the complete carrying setup, cables and battery extensions before choosing this model for travel.
  • unknown: AC output, Surge output

Models: AFERIY

Compare nearby capacity records from the same brand, then check output, weight and missing fields. A larger battery does not establish device compatibility.

AFERIY P040

256 Wh · AC output: 400 W · Confidence: Verified

AFERIY P010

512 Wh · AC output: 800 W · Confidence: Estimated

AFERIY P110-D

960 Wh · AC output: 1,200 W · Confidence: Verified