Yoshino B2000 SST Runtime Calculator

Quick answer: the Yoshino B2000 SST stores 1,326 Wh and delivers up to 2,000 W of continuous AC power. Under this site's planning assumptions (85% inverter efficiency, 10% reserve), a steady 100 W AC load runs for roughly 10.1 hours. Last source check: 2026-08-20. This is an estimate, not a guarantee.

Yoshino B2000 SST portable power station
Battery capacity1,326 Wh
AC output2,000 W
Surge output3,000 W
Battery chemistrySolid-State Li-NCM
ConfidenceVerified
Source regionGlobal/general sources
checked2026-08-20
Swipe table sideways
Yoshino B2000 SST: Key facts
Battery capacity1,326 Wh
Battery chemistrySolid-State Li-NCM
AC output2,000 W
Surge output3,000 W
DC output126 W
USB-C output100 W
Solar input600 W
Weight14.2 kg
ConfidenceVerified
Lifecycle statusUnknown
Source regionGlobal/general sources
Last verified2026-08-20
Catalog notes (original English)

Solid-State Li-NCM is Yoshino's manufacturer label, not an independent chemistry verification.

Runtime estimate

Formula starting points use each scenario’s default watts, duty cycle and output path, with 10% reserve or 15% for CPAP. Linked detail pages use the same inputs. Hours apply only if the device can run and start; they are not measured runtimes.

Swipe table sideways
Runtime estimate
Device scenarioPlanning defaultEstimated runtimeDevice scenario: ConfidenceModels
Full-size refrigerator500 W · 33% · AC inverter · Reserve: 10%6h 9m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
CPAP without heated humidifier40 W · 100% · AC inverter · Reserve: 15%23h 57m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
Starlink Mini32 W · 100% · USB-C PD · Reserve: 10%1d 10h
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
Wi-Fi router12 W · 100% · AC inverter · Reserve: 10%3d 15h
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
LED TV100 W · 100% · AC inverter · Reserve: 10%10h 9m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator

Runtime calculator

Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

Loading calculatorPreparing calculator
Power station model
Battery capacity (Wh): 1326 WhContinuous output rating (W): 2000 WSurge output rating (W): 3000 W
Yoshino B2000 SST
Estimated runtime16h 54m10h 35m – 21h 0mEstimated runtime: 16h 54m, 10h 35m – 21h 0m
Output path

Estimated runtime

Within the tracked power limits; compatibility still needs checking

This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

16h 54mEstimated runtime: 16h 54m

This setup has comfortable headroom for overnight use, assuming the wattage estimate is realistic.

Conservative10h 35m
Estimated16h 54m
Optimistic21h 0m

These are calculated sensitivity cases, not a statistical confidence interval. Conservative uses lower efficiency and battery health, more reserve/temperature loss and higher load; optimistic changes these assumptions in the opposite direction.

  • This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.
  • Within the tracked power limits; compatibility still needs checking

Show your work

Rated Wh is reduced by efficiency, reserve, battery health, and temperature before it is divided by average load.

Rated battery
1326 Wh
Usable energy
1014 Wh
1326 Wh x 85% x 90% x 100% x 100%
Running watts
60 W
Average load
60 W
Max surge
n/a
Fixed station overhead
Unknown (not included)
60 W / 85% = 70.6 W battery draw; fixed overhead is unknown and excluded
Estimated runtime
16h 54m
1014 Wh / 60 W = 16h 54m
Output path
AC inverter
Efficiency (%)
85
Reserve kept unused (%)
10
Battery health (%)
100
Cold weather loss (%)
0

This link contains the numeric values you entered, but not custom load names.

Source-Backed Next Steps

Planning notes

  • Capacity class: 1,326 Wh. Size the battery for your measured average load and required hours, including reserve.
  • Tracked output: 2,000 W. Compare both running demand and startup demand before using any runtime estimate.
  • Solar input limit: 600 W. Actual refill depends on panel voltage/current compatibility, sunlight, angle and charging losses.

Known data gaps

  • Unverified or missing specifications remain visible. The confidence label describes the station record, not a tested runtime or approval for emergency use.
  • Weight: 14.2 kg. Check the complete carrying setup, cables and battery extensions before choosing this model for travel.
  • unknown: —

Models: Yoshino

Compare nearby capacity records from the same brand, then check output, weight and missing fields. A larger battery does not establish device compatibility.

Sources