Westinghouse iGen400s Runtime Calculator

Quick answer: the Westinghouse iGen400s stores 183.6 Wh and delivers up to 200 W of continuous AC power. Under this site's planning assumptions (85% inverter efficiency, 10% reserve), a steady 100 W AC load runs for roughly 1.4 hours. Last source check: 2026-08-21. This is an estimate, not a guarantee.

Westinghouse iGen400s portable power station
Battery capacity183.6 Wh
AC output200 W
Surge output400 W
Battery chemistryLithium-Ion (NCM)
ConfidenceVerified
Source regionGlobal/general sources
checked2026-08-21
Swipe table sideways
Westinghouse iGen400s: Key facts
Battery capacity183.6 Wh
Battery chemistryLithium-Ion (NCM)
AC output200 W
Surge output400 W
DC output150 W
USB-C output100 W
Solar input100 W
Weight2.51 kg
ConfidenceVerified
Lifecycle statusUnknown
Source regionGlobal/general sources
Last verified2026-08-21
Catalog notes (original English)

The 100W USB-C value is the highest published single-port ceiling, not a sum across the three 30W ports and one 100W port. Product weight converts the official 5.53 lb figure to 2.51 kg. The formal specification's 200W rated / 400W peak pair is stored; the manual's separate 300W intended-use wording is not substituted for either rating.

Runtime estimate

Formula starting points use each scenario’s default watts, duty cycle and output path, with 10% reserve or 15% for CPAP. Linked detail pages use the same inputs. Hours apply only if the device can run and start; they are not measured runtimes.

Swipe table sideways
Runtime estimate
Device scenarioPlanning defaultEstimated runtimeDevice scenario: ConfidenceModels
Full-size refrigerator500 W · 33% · AC inverter · Reserve: 10%51m
Exceeds a tracked power limit — do not rely on these hours
EstimatedCalculator
CPAP without heated humidifier40 W · 100% · AC inverter · Reserve: 15%3h 19m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
Starlink Mini32 W · 100% · USB-C PD · Reserve: 10%4h 45m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
Wi-Fi router12 W · 100% · AC inverter · Reserve: 10%12h 7m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
LED TV100 W · 100% · AC inverter · Reserve: 10%1h 24m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator

Runtime calculator

Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

Loading calculatorPreparing calculator
Power station model
Battery capacity (Wh): 184 WhContinuous output rating (W): 200 WSurge output rating (W): 400 W
Westinghouse iGen400s
Estimated runtime2h 21m1h 28m – 2h 55mEstimated runtime: 2h 21m, 1h 28m – 2h 55m
Output path

Estimated runtime

Within the tracked power limits; compatibility still needs checking

This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

2h 21mEstimated runtime: 2h 21m

This setup is tight. Reduce load, use DC where possible, or choose a larger station.

Conservative1h 28m
Estimated2h 21m
Optimistic2h 55m

These are calculated sensitivity cases, not a statistical confidence interval. Conservative uses lower efficiency and battery health, more reserve/temperature loss and higher load; optimistic changes these assumptions in the opposite direction.

  • This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.
  • Within the tracked power limits; compatibility still needs checking

Show your work

Rated Wh is reduced by efficiency, reserve, battery health, and temperature before it is divided by average load.

Rated battery
184 Wh
Usable energy
141 Wh
184 Wh x 85% x 90% x 100% x 100%
Running watts
60 W
Average load
60 W
Max surge
n/a
Fixed station overhead
Unknown (not included)
60 W / 85% = 70.6 W battery draw; fixed overhead is unknown and excluded
Estimated runtime
2h 21m
141 Wh / 60 W = 2h 21m
Output path
AC inverter
Efficiency (%)
85
Reserve kept unused (%)
10
Battery health (%)
100
Cold weather loss (%)
0

This link contains the numeric values you entered, but not custom load names.

Source-Backed Next Steps

Planning notes

  • Capacity class: 183.6 Wh. Size the battery for your measured average load and required hours, including reserve.
  • Tracked output: 200 W. Compare both running demand and startup demand before using any runtime estimate.
  • Solar input limit: 100 W. Actual refill depends on panel voltage/current compatibility, sunlight, angle and charging losses.

Known data gaps

  • Unverified or missing specifications remain visible. The confidence label describes the station record, not a tested runtime or approval for emergency use.
  • Weight: 2.51 kg. Check the complete carrying setup, cables and battery extensions before choosing this model for travel.
  • unknown: —

Models: Westinghouse

Compare nearby capacity records from the same brand, then check output, weight and missing fields. A larger battery does not establish device compatibility.

Sources