Ionic GenBox 100 Runtime Calculator
Quick answer: the Ionic GenBox 100 stores 99.2 Wh and delivers up to 100 W of continuous AC power. Under this site's planning assumptions (85% inverter efficiency, 10% reserve), a steady 100 W AC load runs for roughly 0.8 hours. Last source check: 2026-08-27. This is an estimate, not a guarantee.
| Battery capacity | 99.2 Wh |
|---|---|
| Battery chemistry | LiFePO4 |
| AC output | 100 W |
| Surge output | unknown |
| DC output | unknown |
| USB-C output | 27 W |
| Solar input | 100 W |
| Weight | 1.1 kg |
| Confidence | Estimated |
| Lifecycle status | Unknown |
| Source region | Global/general sources |
| Last verified | 2026-08-27 |
The GenBox 100 is the only model in the Ionic range with a modified sine wave inverter rather than pure sine, so avoid it for CPAP machines, medical equipment and motor-driven appliances that require a clean waveform. Its sub-100Wh pack makes it the one GenBox that is generally acceptable as airline carry-on.
Runtime estimate
Formula starting points use each scenario’s default watts, duty cycle and output path, with 10% reserve or 15% for CPAP. Linked detail pages use the same inputs. Hours apply only if the device can run and start; they are not measured runtimes.
| Device scenario | Planning default | Estimated runtime | Device scenario: Confidence | Models |
|---|---|---|---|---|
| Full-size refrigerator | 500 W · 33% · AC inverter · Reserve: 10% | 28m Exceeds a tracked power limit — do not rely on these hours | Estimated | Calculator |
| CPAP without heated humidifier | 40 W · 100% · AC inverter · Reserve: 15% | 1h 48m Within the tracked power limits; compatibility still needs checking | Estimated | Calculator |
| Starlink Mini | 32 W · 100% · USB-C PD · Reserve: 10% | 2h 34m Exceeds a tracked power limit — do not rely on these hours | Estimated | Calculator |
| Wi-Fi router | 12 W · 100% · AC inverter · Reserve: 10% | 6h 33m Within the tracked power limits; compatibility still needs checking | Estimated | Calculator |
| LED TV | 100 W · 100% · AC inverter · Reserve: 10% | 46m Within the tracked power limits; compatibility still needs checking | Estimated | Calculator |
Runtime calculator
Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.
Something blocked the calculator from starting. Check your connection or reload the page to try again.
Estimated runtime
Within the tracked power limits; compatibility still needs checking
This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.
1h 16mEstimated runtime: 1h 16mThis setup is tight. Reduce load, use DC where possible, or choose a larger station.
These are calculated sensitivity cases, not a statistical confidence interval. Conservative uses lower efficiency and battery health, more reserve/temperature loss and higher load; optimistic changes these assumptions in the opposite direction.
- This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.
- Within the tracked power limits; compatibility still needs checking
Show your work
Rated Wh is reduced by efficiency, reserve, battery health, and temperature before it is divided by average load.
- Rated battery
- 99 Wh
- Usable energy
- 76 Wh
- 99 Wh x 85% x 90% x 100% x 100%
- Running watts
- 60 W
- Average load
- 60 W
- Max surge
- n/a
- Fixed station overhead
- Unknown (not included)
- 60 W / 85% = 70.6 W battery draw; fixed overhead is unknown and excluded
- Estimated runtime
- 1h 16m
- 76 Wh / 60 W = 1h 16m
- Output path
- AC inverter
- Efficiency (%)
- 85
- Reserve kept unused (%)
- 10
- Battery health (%)
- 100
- Cold weather loss (%)
- 0
This link contains the numeric values you entered, but not custom load names.
WattRunTime.com
WattRunTime estimate
Estimated runtime
1h 16mThis setup is tight. Reduce load, use DC where possible, or choose a larger station.Runtime range
Show your work
Rated Wh is reduced by efficiency, reserve, battery health, and temperature before it is divided by average load.
Assumptions
- 99 Wh nominal battery capacity
- AC inverter output path
- 85% conversion efficiency
- 10% reserve kept unused
- 60 W average load from 1 load
- 100% battery health
- 0% temperature loss
- Fixed station overhead unknown; not included
Warnings
- This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.
- Within the tracked power limits; compatibility still needs checking
Share URL
Planning notes
- Capacity class: 99.2 Wh. Size the battery for your measured average load and required hours, including reserve.
- Tracked output: 100 W. Compare both running demand and startup demand before using any runtime estimate.
- Solar input limit: 100 W. Actual refill depends on panel voltage/current compatibility, sunlight, angle and charging losses.
Known data gaps
- Unverified or missing specifications remain visible. The confidence label describes the station record, not a tested runtime or approval for emergency use.
- Weight: 1.1 kg. Check the complete carrying setup, cables and battery extensions before choosing this model for travel.
- unknown: Surge output, DC output
Models: Ionic
Compare nearby capacity records from the same brand, then check output, weight and missing fields. A larger battery does not establish device compatibility.
Ionic GenBox 400
256 Wh · AC output: 400 W · Confidence: Estimated
Ionic GenBox 800
512 Wh · AC output: 800 W · Confidence: Estimated
Ionic GenBox 1200
960 Wh · AC output: 1,200 W · Confidence: Estimated
Sources
- Ionic official GenBox 100 specification table (Official; checked 2026-08-27)