Growatt HELIOS 3600 Runtime Calculator

Quick answer: the Growatt HELIOS 3600 stores 3,686.4 Wh and delivers up to 3,600 W of continuous AC power. Under this site's planning assumptions (85% inverter efficiency, 10% reserve), a steady 100 W AC load runs for roughly 28.2 hours. Last source check: 2026-08-07. This is an estimate, not a guarantee.

Growatt HELIOS 3600 portable power station
Battery capacity3,686.4 Wh
AC output3,600 W
Surge outputunknown
Battery chemistryLiFePO4
ConfidenceEstimated
Source regionGlobal/general sources
checked2026-08-07
Swipe table sideways
Growatt HELIOS 3600: Key facts
Battery capacity3,686.4 Wh
Battery chemistryLiFePO4
AC output3,600 W
Surge outputunknown
DC output396 W
USB-C output100 W
Solar input2,000 W
Weight45 kg
ConfidenceEstimated
Lifecycle statusUnknown
Source regionGlobal/general sources
Last verified2026-08-07
Catalog notes (original English)

Surge output stays unknown because the checked official table publishes rated AC output per outlet group without a peak rating. The 3600W figure is the published total across the four 20A outlets; the same table lists a separate 2200W 240V outlet. DC output uses the listed 13.2V/30A Anderson port. Expansion batteries are sold separately and are not modeled here.

Runtime estimate

Formula starting points use each scenario’s default watts, duty cycle and output path, with 10% reserve or 15% for CPAP. Linked detail pages use the same inputs. Hours apply only if the device can run and start; they are not measured runtimes.

Swipe table sideways
Runtime estimate
Device scenarioPlanning defaultEstimated runtimeDevice scenario: ConfidenceModels
Full-size refrigerator500 W · 33% · AC inverter · Reserve: 10%17h 5m
Output or startup compatibility is not established
EstimatedCalculator
CPAP without heated humidifier40 W · 100% · AC inverter · Reserve: 15%2d 18h
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
Starlink Mini32 W · 100% · USB-C PD · Reserve: 10%3d 23h
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
Wi-Fi router12 W · 100% · AC inverter · Reserve: 10%10d 3h
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
LED TV100 W · 100% · AC inverter · Reserve: 10%1d 4h
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator

Runtime calculator

Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

Loading calculatorPreparing calculator
Power station model
Battery capacity (Wh): 3686 WhContinuous output rating (W): 3600 WSurge output rating (W): n/a
Growatt HELIOS 3600
Estimated runtime1d 23h1d 5h – 2d 10hEstimated runtime: 1d 23h, 1d 5h – 2d 10h
Output path

Estimated runtime

Within the tracked power limits; compatibility still needs checking

This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

1d 23hEstimated runtime: 1d 23h

This setup has comfortable headroom for overnight use, assuming the wattage estimate is realistic.

Conservative1d 5h
Estimated1d 23h
Optimistic2d 10h

These are calculated sensitivity cases, not a statistical confidence interval. Conservative uses lower efficiency and battery health, more reserve/temperature loss and higher load; optimistic changes these assumptions in the opposite direction.

  • This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.
  • Within the tracked power limits; compatibility still needs checking

Show your work

Rated Wh is reduced by efficiency, reserve, battery health, and temperature before it is divided by average load.

Rated battery
3686 Wh
Usable energy
2820 Wh
3686 Wh x 85% x 90% x 100% x 100%
Running watts
60 W
Average load
60 W
Max surge
n/a
Fixed station overhead
Unknown (not included)
60 W / 85% = 70.6 W battery draw; fixed overhead is unknown and excluded
Estimated runtime
1d 23h
2820 Wh / 60 W = 1d 23h
Output path
AC inverter
Efficiency (%)
85
Reserve kept unused (%)
10
Battery health (%)
100
Cold weather loss (%)
0

This link contains the numeric values you entered, but not custom load names.

Source-Backed Next Steps

Planning notes

  • Capacity class: 3,686.4 Wh. Size the battery for your measured average load and required hours, including reserve.
  • Tracked output: 3,600 W. Compare both running demand and startup demand before using any runtime estimate.
  • Solar input limit: 2,000 W. Actual refill depends on panel voltage/current compatibility, sunlight, angle and charging losses.

Known data gaps

  • Unverified or missing specifications remain visible. The confidence label describes the station record, not a tested runtime or approval for emergency use.
  • Weight: 45 kg. Check the complete carrying setup, cables and battery extensions before choosing this model for travel.
  • unknown: Surge output

Models: Growatt

Compare nearby capacity records from the same brand, then check output, weight and missing fields. A larger battery does not establish device compatibility.

Sources