A-iPower GS350i Runtime Calculator

Quick answer: the A-iPower GS350i stores 332.2 Wh and delivers up to 350 W of continuous AC power. Under this site's planning assumptions (85% inverter efficiency, 10% reserve), a steady 100 W AC load runs for roughly 2.5 hours. Last source check: 2026-10-25. This is an estimate, not a guarantee.

A-iPower GS350i portable power station
Battery capacity332.2 Wh
AC output350 W
Surge output700 W
Battery chemistryLithium-ion NMC
ConfidenceEstimated
Source regionUS source
checked2026-10-25
A-iPower GS350i: Key facts
Battery capacity332.2 Wh
Battery chemistryLithium-ion NMC
AC output350 W
Surge output700 W
DC output108.8 W
USB-C output65 W
Solar input100 W
Weight3 kg
ConfidenceEstimated
Lifecycle statusUnknown
Source regionUS source
Last verified2026-10-25
Catalog notes (original English)

US 120V model. The 332.2Wh capacity and weight follow the exact-model manual, corroborated by product bullets, rather than the conflicting product table. The 108.8W DC ceiling is 13.6V x 8A on the car output; the two 12V DC5521 ports are limited to 4A each and share an 8A limit with the car output. USB-C stores 65W per port, not the 130W combined total. The manual's main table and product page agree on 350W continuous AC, although one port diagram says 300W total; check the rating label before planning a load near that limit.

Regional source note Some specs are cross-checked against official regional pages. Regional SKUs can differ; verify the manufacturer page for your market before purchase or emergency planning. aipower.com: A-iPower GS350i US product page and source conflicts, cdn.shopify.com: A-iPower official GS350i manual

Runtime estimate

Formula starting points use each scenario’s default watts, duty cycle and output path, with 10% reserve or 15% for CPAP. Linked detail pages use the same inputs. Hours apply only if the device can run and start; they are not measured runtimes.

Swipe table sideways
Runtime estimate
Device scenarioPlanning defaultEstimated runtimeDevice scenario: ConfidenceModels
Full-size refrigerator500 W · 33% · AC inverter · Reserve: 10%1h 32m
Exceeds a tracked power limit — do not rely on these hours
EstimatedCalculator
CPAP without heated humidifier40 W · 100% · AC inverter · Reserve: 15%6h 0m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
Starlink Mini32 W · 100% · USB-C PD · Reserve: 10%8h 36m
Exceeds a tracked power limit — do not rely on these hours
EstimatedCalculator
Wi-Fi router12 W · 100% · AC inverter · Reserve: 10%21h 56m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator
LED TV100 W · 100% · AC inverter · Reserve: 10%2h 32m
Within the tracked power limits; compatibility still needs checking
EstimatedCalculator

Runtime calculator

Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

Loading calculatorPreparing calculator
Power station model
Battery capacity (Wh): 332 WhAC inverter: 350 WSurge output rating (W): 700 W
A-iPower GS350i
Estimated runtime4h 14m2h 39m – 5h 15m

Within the tracked power limits; compatibility still needs checking

Estimated runtime: 4h 14m. 2h 39m – 5h 15m. Within the tracked power limits; compatibility still needs checking
Output path

Estimated runtime

Within the tracked power limits; compatibility still needs checking

This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.

4h 14mEstimated runtime: 4h 14m. 2h 39m – 5h 15m. Within the tracked power limits; compatibility still needs checking

This setup is tight. Reduce load, use DC where possible, or choose a larger station.

Conservative2h 39m
Estimated4h 14m
Optimistic5h 15m

These are calculated sensitivity cases, not a statistical confidence interval. Conservative uses lower efficiency and battery health, more reserve/temperature loss and higher load; optimistic changes these assumptions in the opposite direction.

  • This is an estimate. Real runtime changes with load, temperature, battery age, AC/DC output, and device behavior. Runtime is conditional on successful startup, compatible voltage/connectors and sufficient output. Verify the actual device setup before relying on these hours.
  • Within the tracked power limits; compatibility still needs checking

Show your work

Rated Wh is reduced by efficiency, reserve, battery health, and temperature before it is divided by average load.

Rated battery
332 Wh
Usable energy
254 Wh
332 Wh x 85% x 90% x 100% x 100%
Running watts
60 W
Average load
60 W
Max surge
n/a
Fixed station overhead
Unknown (not included)
60 W / 85% = 70.6 W battery draw; fixed overhead is unknown and excluded
Estimated runtime
4h 14m
254 Wh / 60 W = 4h 14m
Output path
AC inverter
Efficiency (%)
85
Reserve kept unused (%)
10
Battery health (%)
100
Cold weather loss (%)
0

This link contains the numeric values you entered, but not custom load names.

Source-Backed Next Steps

Planning notes

  • Capacity class: 332.2 Wh. Size the battery for your measured average load and required hours, including reserve.
  • Tracked output: 350 W. Compare both running demand and startup demand before using any runtime estimate.
  • Solar input limit: 100 W. Actual refill depends on panel voltage/current compatibility, sunlight, angle and charging losses.

Known data gaps

  • Unverified or missing specifications remain visible. The confidence label describes the station record, not a tested runtime or approval for emergency use.
  • Weight: 3 kg. Check the complete carrying setup, cables and battery extensions before choosing this model for travel.

Models: A-iPower

Compare nearby capacity records from the same brand, then check output, weight and missing fields. A larger battery does not establish device compatibility.