Target-duration planning

Run a fridge for 24 hours from a power station

Start from the outage duration, then reverse the runtime formula using the refrigerator scenario's sourced wattage range and duty-cycle assumption.

Target

24 hours

Planning load

165 W

  • Running watts: 500 W
  • Duty cycle (%): 33%

Estimated nominal battery

5,200 Wh+

Scenario confidence

estimated

Verify your watts

  • Check the device label for running watts or input amps and volts.
  • Use a plug-in watt meter for AC loads when the result matters.
  • For cycling loads, measure long enough to capture on/off behavior.

Open wattage library

Check output path

  • AC inverter loads usually lose more energy than direct DC loads.
  • Keep reserve for cold weather, battery age, and load changes.
  • Do not treat label capacity as fully usable watt-hours.

Read the method

Check surge and output

  • Runtime does not prove a station can start a compressor or motor.
  • Compare device startup watts with the station surge rating.
  • Compare running watts with the station continuous output rating.

Check startup surge

Reverse runtime formula

This page solves for battery Wh instead of asking how long a battery lasts.

Load energy

165 W × 24 hours = 3,960 Wh

Usable factor

85% × 90% × 100% × 100% = 0.77

Estimated nominal battery

3,960 Wh ÷ 0.77 ≈ 5,200 Wh

Scenario behavior

A refrigerator is treated as a cycling compressor load. The running-watt default is averaged by duty cycle, so ambient temperature, door openings, and thermostat settings can move the result.

Wh-class guidance

Use the computed Wh as a planning floor. Choose a larger class when the room is hot, the fridge is older, the battery is aged, or startup surge/output headroom is unknown.

Assumptions used

  • Full-size refrigerator: 300-800 W
  • Efficiency (%): 85%
  • Reserve kept unused (%): 10%
  • Output path: AC inverter
  • Battery health (%): 100%
  • Cold weather loss (%): 0%

Caveats

  • Measure the fridge if food safety depends on the plan.
  • Runtime math does not prove the station can start the compressor; check startup surge separately.
  • Solar input can help during daylight, but this page sizes the battery without assuming solar recovery.

Sources

Fridges cycle on and off. The calculator treats the entered wattage as compressor running wattage and applies a duty-cycle estimate.

Next steps

Start from the outage duration, then reverse the runtime formula using the refrigerator scenario's sourced wattage range and duty-cycle assumption.